During the development of chemical methods for determining the epoxide content of epoxidised natural rubber (ENR) two methods were found to give results which were identical but which showed a progressive divergence from values obtained by absolute instrumental methods as the level of epoxidation increased. Statistical analysis of the sequence distribution of the epoxide groups, based on a random epoxidation, showed a good correlation between the value obtained by chemical analysis and the number of epoxide blocks rather than the number of epoxide groups. Two further instrumental methods for measuring the total epoxide content, using infra red spectroscopy and differential scanning calorimetry, were developed. Analytical procedures and calibration data are supplied. A combination of one chemical and one instrumental method can thus provide the absolute level of epoxidation and indicate whether the reaction has proceeded randomly or not, a point of crucial importance in the large scale manufacture of this material.
No takes yet. Share an insight, caveat, or question.
Davey et al. (1984) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: