Key result
Box-counting fractal dimension may characterize LDF time series signals with weak temporal correlation.
Why the study?
The fractal behavior of Laser Doppler Flow signals and their fractal dimension as a measure of temporal variability in tissue perfusion were not quantitatively characterized.
Observational
The Box-counting method for determining fractal dimension may be a useful technique for characterizing LDF time series signals to quantify microvascular dysfunction.
Fractal analysis of LDF signals may refine microcirculation assessment; leaves open clinical adoption pending prospective validation.
Laser Doppler Blood Flow meter uses tissue backscattered light to non-invasively assess the blood flow rate. qualitatively. As there is large spatial variability and the temporal heterogeneity in tissue microvasculature, the measured blood flow rate is expressed in relative units. A non-linear approach in order to understand the dynamics of the microcirculation led to the fractal characterization of the blood flow signals. The study presented in the paper aims to analyze the fractal behavior of Laser Doppler Flow (LDF) signals and to quantitatively estimate the fractal dimension of waveforms using Box-Counting method. The measured Fractal dimension is an estimate of temporal variability of tissue perfusion. The rate at which fractal dimension varies as a function of location between individuals, exhibits a weak correlation with time. Further studies with a larger number of subjects are necessary to test the generality of the findings and if changes in dimension are reproducible in given individuals. In conclusion, the fractal dimension determined by Box-counting method may be useful for characterizing LDF time series signals. Future experiments evaluating whether the technique can be used to quantify microvascular dysfunction, as commonly occurring in conditions such as Diabetes, Raynaud's phenomenon, Erythromelalgia and Achenbach syndrome needs to be evaluated.
No takes yet. Share an insight, caveat, or question.
Srinivasan et al. (2011) reported an observational. Fractal dimension characterization of Laser Doppler Flow signals was evaluated on Fractal dimension of waveforms. Fractal dimension determined by the Box-counting method may be useful for characterizing Laser Doppler Flow time series signals, exhibiting a weak correlation with time.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: