Answers are grounded in this paper and cite their sources.
C-labeled test compounds of different physical-chemical properties. Nearly 100% of the compounds added to the sample before extraction could be recovered with an average reproducibility relative standard deviation (CV) of 5.4%. The additional steps of the determination process (cleanup, evaporation, etc.) contributed to the major part of the variability of the results (CV = 10-20%). The incurred residues were most efficiently extracted with acetone for 30 min followed by the mixture of acetone/ethyl acetate 1:1 for additional 30 min. However, they could only be recovered at various extent (64-90% of total residues), underlying the importance of testing the efficiency of extraction. The residues were identified and quantified by gas chromatography applying thermionic detector. The performance parameters of the method complied with the international method validation guidelines, and they proved to be robust and suitable for determination of pesticide residues in soils of widely different physical-chemical properties.
No takes yet. Share an insight, caveat, or question.
Suszter et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: