Key result
N20 SER component remains the most stable during uncomplicated CEA with latency fluctuating <1.5 msec.
Why the study?
The criteria for defining abnormal somatosensory evoked responses during carotid endarterectomy are largely arbitrary and require analysis of normal variability in uncomplicated cases.
What is the normal variability of early scalp-components of the somatosensory evoked response during uncomplicated, unshunted carotid endarterectomy?
Observational (n=23)
What is the normal variability of early scalp-components of the somatosensory evoked response during uncomplicated, unshunted carotid endarterectomy?
The N20 component of the somatosensory evoked response is the most stable short-latency component during uncomplicated carotid endarterectomy and should be relied upon to predict abnormalities.
Answers are grounded in this paper and cite their sources.
N20 stability provides normative data for carotid endarterectomy monitoring; extends small-cohort observations but leaves open outcome impact in prospective trials.
Although many publications deal with the usefulness of the SER in CEAs, the criteria of calling a SER abnormal during a CEA are largely arbitrary. One way to define the limits of normalcy for SERs during the CEA will be to analyze the SER tracings obtained during unshunted and uncomplicated (intra- and postoperative) CEAs. In 23 such CEAs (10 right, 13 left; clamptime 10-23 mins.), data analysis at the ipsilateral parietal electrode, on stimulation of the contralateral median nerve (square pulse -5.1/sec, 10-30 V, 200 microseconds; bandpass-30-3000 Hz trials-500 stimuli), revealed that (1) latency fluctuations of the N20 (21.4 msec) were narrowest, being less than 1.5 msec different during and after clamping compared to the preclamp latency in all 23 CEAs, whereas those of P25 (27.4 msec) and N35 (38.5 msec) were greater than 2.0 msec different from the preclamp latency in 3 and 8 CEAs respectively, and (2) the amplitudes of N20, P25 and N35 measured from the preceding peak of opposite polarity, fell to less than 75% of the preclamp value on 3, 4 and 7 CEAs respectively. It is concluded that N20 was the most stable of the first three short-latency components in the SER and should perhaps be most relied upon to predict abnormality of the SER during CEAs.
No takes yet. Share an insight, caveat, or question.
Verma et al. (1985) conducted an observational in Uncomplicated, unshunted carotid endarterectomy (n=23). Carotid clamping during CEA vs. Preclamp baseline was evaluated on Latency and amplitude fluctuations of N20, P25, and N35 components of SER. During uncomplicated carotid endarterectomy, the N20 component of the somatosensory evoked response was the most stable, with latency fluctuating less than 1.5 msec in all 23 cases.