Experimental evaluation demonstrates high fracture toughness in upscaled tungsten fibre-reinforced composites, suggesting their viability as resilient armour materials for fusion reactors.
Tungsten fibre-reinforced tungsten composites (Wf/W) have been in development to overcome the inherent brittleness of tungsten as one of the most promising candidate for the first wall and divertor armour material in a future fusion power plant. As the development of Wf/W continues, the fracture toughness of the composite is one of the main design drivers. In this contribution the efforts on size upscaling of Wf/W based on Chemical Vapour Deposition (CVD) is shown together with fracture mechanical tests of two different size samples of Wf/W produced by CVD. Three-point bending tests according to ASTM E399 for brittle materials were used to get a first estimation of the toughness. A provisional fracture toughness value of up to 346MPam1/2 was calculated for the as-fabricated material. As the material does not show a brittle fracture in the as-fabricated state, the J-Integral approach based on the ASTM E1820 was additionally applied for this state. A maximum value of the J-integral of 41kJ/m2 (134,8MPam1/2) was determined for the largest samples. Post mortem investigations were employed to detail the active mechanisms and crack propagation.