The currents and load voltage of a 2-branch resistance-inductance parallel circuit controlled by an SCR pair in the supply line are deduced. While the SCRs are nonconducting, current decays exponentially around the load loop. The extinction angle is a transcendental function of the load impedances and (implicitly) the supply voltage. There is close agreement between measured and calculated results. The system cannot be analyzed in terms of a single-impedance equivalent load.
No takes yet. Share an insight, caveat, or question.
W. Shepherd (1966) studied this question.