Diaphragm compressors in hydrogen refueling stations are frequently subjected to off-design operation, making their flowrate characteristics essential for evaluating station refueling efficiency. In this study, a theoretical calculation model is developed to analyze the flowrate characteristics of a single-stage 45 MPa diaphragm compressor under a wide range of operating conditions. The model accuracy is validated against using volumetric efficiency data obtained during the pressurization process in a hydrogen refueling station. The results indicate that the measured flowrates agree well with the calculated values, with a maximum relative error not exceeding 5%. The effects of compression ratio and oil-gas pressure differential on the clearance expansion, oil expansion, valve loss and suction heating factors are further analyzed to reveal the mechanisms affecting the flowrate. Finally, a full-range volumetric-efficiency map is established and applied to storage-bank repressurization after vehicle refueling, supporting hydrogen supply optimization and practical refueling strategies.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: