Answers are grounded in this paper and cite their sources.
This aper describes a non-counting decimal-coded shaft digitizer. Phototubes are used to read the posi-of masks, permitting static as well as dynamic readout with minimum loading of the measured shaft. Reading is done with several units, each reading a digit of the decimal number representing the shaft position. A special decimal code enmploying 5 phototubes per decade is used to avoid intra-decade ambiguities. Inter-decade ambiguities are prevented by using two masks on all but the first decade. An experimental digitizer, using standard components, is described.
No takes yet. Share an insight, caveat, or question.
Libaw et al. (1953) studied this question.