Answers are grounded in this paper and cite their sources.
Background:Wearable devices equipped with inertial sensors enable objective gait assessment for persons with multiple sclerosis (MS), with potential use in ambulatory care or home and community-based assessments. However, gait data collected in non-controlled settings is often fragmented and may not provide enough information for reliable measures. We evaluate a novel approach, extracting pre-defined numbers of gait cycles from the full length of a walking task, and their effects on the reliability of spatiotemporal gait parameters.Methods:The present study evaluates intra-session reliability of spatiotemporal gait parameters for short bouts of gait data extracted from the full length of the walking tasks to 1) determine the effects of the length of the walking task on the reliability of calculated measures and 2) identify spatiotemporal gait parameters that can provide reliable measures for gait assessments and reference data in different settings.Thirty-seven participants (37) diagnosed with relapsing-remitting MS (EDSS rage 0 to 4.5) executed two trials, walking 20m each, with inertial sensors attached to their right and left shanks. Previously published algorithms were applied to identify gait events from the medio-lateral angular velocity. Short bouts of gait data were extracted from each trial, with lengths varying from 3 to 9 gait cycles. Twenty-one measures of spatiotemporal gait parameters were calculated. Intraclass correlation coefficients (ICCs) were calculated to evaluate how the degree of agreement between the two trials of each participant varied with the number of gait cycles included in the analysis.Results:Spatiotemporal gait parameters calculated as the mean across included gait cycles reach excellent reliability from three gait cycles. Stride time variability and asymmetry, as well as stride velocity variability and asymmetry, reach good reliability from six gait cycles and should be further explored for persons with MS, while stride time asymmetry and step time asymmetry do not seem to provide reliable measures and should be reported carefully.Conclusion:Short bouts of gait data, including at least six gait cycles of bilateral data, can provide reliable gait measurements for persons with MS, opening new perspectives for gait assessment using wearable devices in non-controlled environments, to support monitoring of symptoms of persons with neurological diseases.Trial registrationNot applicable.
No takes yet. Share an insight, caveat, or question.
Motti et al. (2020) studied this question.