Key result
Unified biaxial testing characterizes nonlinear mechanics of atrioventricular valve leaflets.
Why the study?
Extensive biaxial mechanical testing of atrioventricular heart valve leaflets is needed to derive optimal parameters for constitutive models representing their mechanical function.
The presented biaxial testing procedure allows for a comprehensive characterization of atrioventricular valve leaflet tissue mechanics under a unified testing scheme.
Supports parameter derivation for AV valve models; leaves open clinical translation pending validation.
Extensive biaxial mechanical testing of the atrioventricular heart valve leaflets can be utilized to derive optimal parameters used in constitutive models, which provide a mathematical representation of the mechanical function of those structures. This presented biaxial mechanical testing protocol involves (i) tissue acquisition, (ii) the preparation of tissue specimens, (iii) biaxial mechanical testing, and (iv) postprocessing of the acquired data. First, tissue acquisition requires obtaining porcine or ovine hearts from a local Food and Drug Administration-approved abattoir for later dissection to retrieve the valve leaflets. Second, tissue preparation requires using tissue specimen cutters on the leaflet tissue to extract a clear zone for testing. Third, biaxial mechanical testing of the leaflet specimen requires the use of a commercial biaxial mechanical tester, which consists of force-controlled, displacement-controlled, and stress-relaxation testing protocols to characterize the leaflet tissue's mechanical properties. Finally, post-processing requires the use of data image correlation techniques and force and displacement readings to summarize the tissue's mechanical behaviors in response to external loading. In general, results from biaxial testing demonstrate that the leaflet tissues yield a nonlinear, anisotropic mechanical response. The presented biaxial testing procedure is advantageous to other methods since the method presented here allows for a more comprehensive characterization of the valve leaflet tissue under one unified testing scheme, as opposed to separate testing protocols on different tissue specimens. The proposed testing method has its limitations in that shear stress is potentially present in the tissue sample. However, any potential shear is presumed negligible.
No takes yet. Share an insight, caveat, or question.
Ross et al. (2019) studied Atrioventricular heart valve mechanical characterization. Unified biaxial mechanical testing protocol vs. Separate testing protocols on different tissue specimens was evaluated on Mechanical properties (stress-stretch response, stress relaxation). A unified biaxial mechanical testing protocol successfully characterized the nonlinear, anisotropic mechanical response of atrioventricular heart valve leaflets under one testing scheme.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: