Experimental study demonstrates bidirectional multikilowatt power conversion without passive low-frequency filters, indicating enhanced response speeds and reduced converter bulk.
An efficient ac-to-dc converter with reversible power flow, which embodies an active, low-frequency filter, is presented. A nondissipatively controlled, nonlinear resonant oscillator is used to extract electric energy directly from the phase pairs of the polyphase supply line and to generate a mixed amplitude-and frequency-modulated carrier. The demodulated carrier and the resulting 20-kHz pulse train produces, after being processed by a high-frequency filter, an active, low-frequency filtering effect for attenuation of the 360-Hz ripple of the apparently ``rectified'' three-phase supply line. The system is governed by means of a pulse area control mechanism with a verified response time of one 10-kHz cycle, or 100 µs. The customary dc link between the three-phase line and the converter's 20-kHz pulse-processing mechanism in the form of a common rectifier-filter is completely eliminated. Data obtained from the test of a 3-kW feasibility model are analyzed in support of the presentation of the significant aspects of design and technology.
No takes yet. Share an insight, caveat, or question.
Schwarz et al. (1981) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: