A radioimmunoassay for the measurement of total thyroxine in unextracted serum or plasma is described. The assay is performed according to the sequential saturation principle in less than 4 h. The entire assay is carried out at room temperature. An antiserum of high affinity was used as binder, ammonium 8-anilino-1-naphthalene-sulphonate as displacing agent, and activated charcoal as adsorbent in the separation step. The standard curve was linear in the range 0-136 nmol/l serum. The precision in terms of SD was nearly the same through-out this range. Estimates of within-assay SD varied from 1.3 to 4.1 and between-assay SD from 0 to 3.3 nmol/l. The recovery of thyroxine added to normal plasma was 100% and the sensitivity was 6 nmol/l. Mean thyroxine concentration in plasma from young bulls was 92 nmol/l. The assay appears to be very well suited for experimental purposes when high precision is essential.
No takes yet. Share an insight, caveat, or question.
Kruse et al. (1977) studied this question.