Answers are grounded in this paper and cite their sources.
We report one-lung ventilation in the patient with laryngeal or tracheal stenosis, which has not been reported previously. Patient 1: A 65-yr-old woman, 137 cm, 53 kg, was scheduled for right lower lobectomy. After the induction of anesthesia, only the posterior half of the glottis was seen at laryngoscopy. The tip of a 37F double-lumen tube (Rüsch, Duluth, GA) was passed through the glottis, but the tube could not be advanced further. Insertion of a 35F double-lumen tube also failed. Fiberscopy revealed congenital laryngeal web. After the blocker part of a Univent tube (Fuji System Corporation, Tokyo, Japan) was taken out by using scissors, the detached blocker was inserted into the trachea, and a 6.0-mm inside diameter (ID) tracheal tube was inserted alongside the blocker with a little resistance. The blocker was then advanced into the right main bronchus under fiberscopy. The operation proceeded uneventfully, and the patient had only a mild sore throat for a few days postoperatively. Patient 2: A 63-yr-old man, 164 cm and 58 kg, was scheduled for right upper lobectomy. Preoperative magnetic resonance imaging showed a saber-sheath trachea (1,2), stenosis of the entire intrathoracic trachea. After the induction of anesthesia, an attempt was made to insert a 6.5-mm ID Univent tube (the smallest tube available at our hospital), but it was removed because there was resistance when the tube reached the stenosis. A detached Univent blocker and a 6.5-mm tracheal tube were inserted into the trachea without difficulty. The blocker was advanced into the right main bronchus under fiberscopy. The operation proceeded uneventfully. If there is a narrowing of the larynx or trachea, neither double-lumen nor the Univent tube may be suitable. It may be possible to insert a double-lumen tube of a small size, but the tube may be too short to reach the bronchus. The Univent tubes also have relatively larger external diameters than single-lumen tubes: even the smallest size (6.0 mm ID: although 3.5 mm ID is available in the United States) has the maximal external diameter of 11.0 mm, the diameter which is roughly equivalent to a 7.5- or 8.0-mm ID single-lumen tube. In the circumstances, the use of a bronchial blocker, such as a Fogarty catheter or a detached blocker from the Univent tube, is useful. Takashi Asai MD, PhD Koh Shingu MD
No takes yet. Share an insight, caveat, or question.
Asai et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: