Key result
Percutaneous VSD occluder successfully repairs inadvertent right atrial wall perforation during transseptal puncture.
Why the study?
Coronary sinus perforation is a life-threatening complication of transseptal puncture that requires immediate repair, and percutaneous closure as an alternative to surgery needs illustration.
Case Report (n=1)
Percutaneous device closure using a ventricular septal occluder is a feasible alternative to surgery for inadvertent free right atrial wall perforation at the coronary sinus during transseptal puncture.
May offer bailout for rare transseptal perforation; hypothesis-generating and should not yet change practice.
Coronary sinus perforation is a life-threatening complication of transseptal puncture and needs to be repaired immediately. In this study, we report a case of a 74-year-old female patient with nonvalvular atrial fibrillation, who is a poor long-term anticoagulation candidate. During the manipulation of transseptal puncture, a perforation of the free right atrial wall at the coronary sinus ostium occurred, which was caused by the Brockenbrough needle and followed by the immediate advancement of an 8.5-French transseptal sheath. In consideration of the danger of cardiac tamponade after sheath removal, we decided to leave the 8.5-French sheath in the pericardial cavity. Then, we advanced a 6 mm ventricular septal occluder through the sheath. Finally, we achieved successful deployment of the device and closure of the perforation under the guidance of fluoroscopy and transthoracic echocardiography. Subsequently, the left atrial appendage orifice was occluded with a 21 mm Watchman device. This case illustrates that percutaneous device closure is feasible for inadvertent perforation of the free right atrial wall at the coronary sinus during transseptal puncture and should be considered as an alternative to surgery.
No takes yet. Share an insight, caveat, or question.
Bai et al. (2019) conducted a case report in Coronary sinus perforation during transseptal puncture in nonvalvular atrial fibrillation (n=1). Percutaneous occlusion with a 6 mm ventricular septal occluder was evaluated on Closure of the perforation. Percutaneous device closure using a 6 mm ventricular septal occluder successfully repaired an inadvertent free right atrial wall perforation at the coronary sinus during transseptal puncture.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: