The effects of certain knitting parameters on the impact force between the needle and the guard cam are described. It is found that increasing the stitch-cam incidence angle increases the guard-cam impact magnitude. The use of much steeper guard-cam angles tends to extend the duration of impact, as expected, but this is accompanied by higher impact-force magnitudes and more frequent needle-butt fractures. Progressively increasing the clearance between the cam and cylinder causes small but clearly discernible reductions in impact magnitude. Reducing the mass of the needle has a large effect in reducing the magnitude of impact but has little effect on its duration. Although no modifications to the shape of the needle butt conclusively reduce guard-cam impact conditions, they indirectly serve to spotlight the adverse effects of slight surface imperfections in the stitch cam. The heavy addition of lubricating oil to the cylinder tricks decreases the impact magnitude and causes the initial impact to occur at a higher velocity.
No takes yet. Share an insight, caveat, or question.
Wray et al. (1978) studied this question.