Answers are grounded in this paper and cite their sources.
The management of cataracts in keratoconus patients poses a challenge due to the irregular corneal shape and variability in corneal topography, which may lead to errors in determining corneal power. In this report, we present a case of a 48-year-old male with a history of keratoconus and prior Visian Implantable Collamer lenses and Corneal Allogenic Intrastromal Ring Segments procedures, who presented with a nuclear cataract in his right eye. To address this patient’s complex case, he underwent ICL explantation, cataract extraction, and intraocular lens (IOL) implantation, utilizing the Johnson & Johnson Sensar AR40 monofocal 3-piece lens with a power of −9.5. The Barrett True K formula predicted a spherical equivalent of −1.76, and at the post-operative one-month follow-up, the uncorrected distance visual acuity (UDVA) was 20/60, with pinhole improvement to 20/50. The manifest refraction was −2.50–3.25 × 145, and the best corrected visual acuity was 20/25. This case report highlights the unique challenges encountered in managing keratoconus patients with a history of prior ICL and CAIRS procedures, followed by cataract extraction. Our findings underscore the importance of a comprehensive approach in the management of progressive keratoconus and cataracts to ensure optimal outcomes.
No takes yet. Share an insight, caveat, or question.
Ali et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: