Answers are grounded in this paper and cite their sources.
We evaluated four recent antibody-detection kits for typhoid fever by using 177 febrile patients from our hospital, in 75 of whom Salmonella enterica serotype Typhi grew. TUBEX performed best, achieving 94.7% sensitivity and 80.4% specificity. Typhidot, SD Bioline Typhoid, and Mega Salmonella were less specific and, in most cases, less sensitive.
No takes yet. Share an insight, caveat, or question.
Kawano et al. (2006) studied this question.