Key result
A decision tree algorithm analyzing B-scan ultrasonic signals correctly classifies ocular tissues with ~96% accuracy.
Why the study?
Noninvasive differentiation of ocular tissues using ultrasound signals requires development of algorithms and decision support systems based on signal characterization.
Can RF ultrasound signal processing algorithms correctly differentiate ocular tissues?
Can RF ultrasound signal processing algorithms correctly differentiate ocular tissues?
Developed algorithms using RF ultrasound signal processing can accurately differentiate between corpus vitreum blood, extraocular muscle, and orbit tissues with only 1 error in 26 cases.
Answers are grounded in this paper and cite their sources.
Feasible for ocular tissue differentiation in small samples; leaves open larger prospective validation before clinical adoption.
Algorithms and software were developed for analysis of B-scan ultrasonic signals acquired from commercial diagnostic ultrasound system. The algorithms process raw ultrasonic signals in backscattered spectrum domain, which is obtained using two time-frequency methods: short-time Fourier and Hilbert-Huang transformations. The signals from selected regions of eye tissues are characterized by parameters: B-scan envelope amplitude, approximated spectral slope, approximated spectral intercept, mean instantaneous frequency, mean instantaneous bandwidth, and parameters of Nakagami distribution characterizing Hilbert-Huang transformation output. The backscattered ultrasound signal parameters characterizing intraocular and orbit tissues were processed by decision tree data mining algorithm. The pilot trial proved that applied methods are able to correctly classify signals from corpus vitreum blood, extraocular muscle, and orbit tissues. In 26 cases of ocular tissues classification, one error occurred, when tissues were classified into classes of corpus vitreum blood, extraocular muscle, and orbit tissue. In this pilot classification parameters of spectral intercept and Nakagami parameter for instantaneous frequencies distribution of the 1st intrinsic mode function were found specific for corpus vitreum blood, orbit and extraocular muscle tissues. We conclude that ultrasound data should be further collected in clinical database to establish background for decision support system for ocular tissue noninvasive differentiation.
No takes yet. Share an insight, caveat, or question.
Jurkonis et al. (2012) studied Ocular tissue differentiation (n=26). Decision tree data mining algorithm using short-time Fourier and Hilbert-Huang transformations on B-scan ultrasonic signals was evaluated on Correct classification of ocular tissues (corpus vitreum blood, extraocular muscle, and orbit tissues). A decision tree algorithm analyzing B-scan ultrasonic signals correctly classified ocular tissues in 25 out of 26 cases.