This is the authors' abstract. We don't add key points for this paper.
Ultrasonic reflection provides a real-time way to monitor oil film thickness in a running machine with a non-destructive advantage. However, the influence mechanism of temperature on reference signals has not been clarified so far, which hinders the precise measurement of oil film thickness. Focusing on a common three-layer structure of sensor-adhesive-steel, a global propagation model is constructed to investigate variations in the reference signal with temperature. Through finite element simulations, distinct influence mechanisms are revealed for different components: For piezoelectric sensors and the adhesive layer, temperature may induce amplitude attenuation and wave extensions in the reference signal. In the steel component, only an overall time shift is observed in the reference signal. Subsequently, a compensation model is established and validated through temperature-controlled experiments. Within the effective bandwidth, the compensation model achieves a relative error of and an absolute error of radians for the amplitude and phase of the reference waves.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Jia et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: