Noise performance of the correlated double sampling switched-capacitor integrators incorporating a supplementary hold capacitor is analyzed. These types of integrators rely on an extra capacitor to attenuate the amplifier low-frequency noise. Approximate expressions for the input-referred noise of the integrators are derived. It is shown that a large parasitic capacitance at the amplifier input may seriously degrade the low-frequency noise performance of such structures.
No takes yet. Share an insight, caveat, or question.
O. Oliaei (2003) studied this question.