Key result
LDL-C monitoring detects complete statin non-adherence with ~0.89 AUC but poorly identifies partial non-adherence.
Why the study?
The accuracy of monitoring cholesterol concentration to detect non-adherence to lipid lowering treatment was uncertain.
Does monitoring cholesterol concentration accurately detect non-adherence to lipid-lowering treatment in patients with previous coronary heart disease?
Observational (n=9,014)
Yes
Does monitoring cholesterol concentration accurately detect non-adherence to lipid-lowering treatment in patients with previous coronary heart disease?
Monitoring LDL or total cholesterol changes has limited utility for reliably detecting partial non-adherence to statin therapy and should only be used as an adjunct to patient discussion.
LDL-C monitoring has limited utility for partial non-adherence post-CHD; leaves open whether combined markers improve detection.
OBJECTIVE: To estimate the accuracy of monitoring cholesterol concentration for detecting non-adherence to lipid lowering treatment. DESIGN: Secondary analysis of data on cholesterol concentration in the LIPID (long term intervention with pravastatin in ischaemic disease) study by using three measures of non-adherence: discontinuation of treatment, allocation to placebo arm, less than 80% of pills taken. SETTING: Randomised placebo controlled trial in Australia and New Zealand. PARTICIPANTS: 9014 patients with previous coronary heart disease. INTERVENTIONS: Pravastatin 40 mg or placebo daily. MAIN OUTCOME MEASURES: Sensitivity, specificity, area under the receiver operating characteristics (ROC) curve, post-test probability. RESULTS: Monitoring of cholesterol concentration had modest ability for detecting complete non-adherence. One year after the start of treatment, half (1957/3937) of the non-adherent patients and 6% (253/3944) of adherent patients had a rise in concentration of low density lipoprotein cholesterol. Accuracy was reasonable (area under the curve 0.89). Cholesterol monitoring, however, had weak ability for detecting partial non-adherence. One year after the start of treatment, 16% (34/213) of partially adherent and 4% (155/3585) of fully adherent patients had a rise in concentration of low density lipoprotein cholesterol. Accuracy was poor (area under the curve 0.65). For typical pre-test probabilities of non-adherence ranging from low (25%) to high (75%), the post-test probabilities indicate continuing uncertainty after lipid testing. A patient with no change in low density lipoprotein cholesterol concentration has a post-test probability of being completely non-adherent of between 67% and 95% and a post-test probability of being partially non-adherent of between 48% and 89%. A patient with a decrease in concentration of 1.0 mmol/L has a post-test probability of being completely non-adherent of between 7% and 40% and a post-test probability of being partially non-adherent of between 21% and 71%. CONCLUSIONS: Monitoring concentration of low density lipoprotein (or total) cholesterol has modest ability to detect complete non-adherence or non-persistence with pravastatin treatment and weak ability to detect partial non-adherence. Results of monitoring should be considered as no more than an adjunct to careful discussion with patients about adherence.
No takes yet. Share an insight, caveat, or question.
Bell et al. (2011) conducted an observational in Previous coronary heart disease (n=9,014). Monitoring cholesterol concentration vs. Adherent patients was evaluated on Accuracy (area under the ROC curve) of change in low density lipoprotein cholesterol for detecting complete non-adherence (using placebo allocation as proxy) (AUC 0.89, 95% CI 0.88-0.89, p=<0.001). Monitoring low-density lipoprotein cholesterol concentration had reasonable accuracy for detecting complete non-adherence (AUC 0.89) but poor accuracy for detecting partial non-adherence (AUC 0.65).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: