This is the authors' abstract. We don't add key points for this paper.
OBJECTIVES: To conduct a diagnostic validation study of SARS-CoV-2 diagnostic kits. METHODS: We compared SARS-CoV-2 diagnostic test results from 3 RT-PCR assays used by the Zambian government between November 2020 and February 2021 (Panther Fusion assay, Da An Gene's 2019-nCoV RNA kit and Maccura's PCR Kit) with the Altona RealStar RT-PCR kit which served as the gold standard. We also evaluated results from rapid antigen testing and whether comorbidities were linked with increased odds of infection. RESULTS: We recruited 244 participants, 61% (149/244) were positive by at least 1 PCR assay. Da An Gene, Maccura, and Panther Fusion assays had sensitivities of 0.0% (95% confidence interval [CI] 0%-41%), 27.1% (95% CI 15%-42%), and 76% (95% CI 65%-85%), respectively, but specificity was low (<85% for all 3 assays). HIV and TB were not associated with SARS-CoV-2, whereas female sex (OR 0.5 [0.3-0.9], p = 0.026) and chronic pulmonary disease (0.1 [0.0-0.8], p = 0.031) were associated with lower odds of SARS-CoV-2 infection. Of 44 samples, 84% sequenced were Beta variant. CONCLUSIONS: The RT-PCR assays evaluated did not meet WHO recommended minimum sensitivity of 80%. Local diagnostic validation studies should be embedded within preparedness plans for future outbreaks to improve the public health response.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Tembo et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: