This is the authors' abstract. We don't add key points for this paper.
Challenging ground-based optical interferometry projects, such as Stokes parameter imaging, require new techniques and instrumentation. In anticipation of such observations, I progress beyond the mathematics of classical optical interferometry (OIC) to optical interferometric polarimetry (OIP). First, I calculate the behavior of a two-channel coherent-averaging OIP instrument. I then define observables that ease instrumental requirements for counteracting atmospheric effects. In general, the output vectors that arise from these observables can be used only for modeling, but if a priori source information is available, images may be created with a single variable baseline. Next, I derive covariances, signal-to-noise ratios, and biases for the observables and output vectors. I also discuss calibration matrices and demonstrate how they are obtained and applied. Last, I present a simple example of OIP data reduction.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
N. M. Elias (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: