Key result
GSO device improves QALYs and saves costs vs. ATO device for PFO closure.
Why the study?
Does the GORE CARDIOFORM Septal Occluder improve cost-effectiveness and clinical outcomes compared to the Amplatzer Talisman PFO Occluder and medical therapy alone in patients with a history of PFO-associated stroke?
Does the GORE CARDIOFORM Septal Occluder improve cost-effectiveness and clinical outcomes compared to the Amplatzer Talisman PFO Occluder and medical therapy alone in patients with a history of PFO-associated stroke?
The GORE CARDIOFORM Septal Occluder is a cost-effective and potentially cost-saving strategy compared to the Amplatzer device and medical therapy alone for preventing recurrent PFO-associated strokes in the UK.
GSO may be cost-effective for PFO closure in UK modeling; leaves open need for direct comparative trials.
Purpose: This study evaluated the cost-effectiveness and budget impact of two patent foramen ovale (PFO) closure devices and medical management for the prevention of recurrent PFO-associated strokes in the UK. Patients and Methods: We used a Markov model to simulate 1000 individuals with a history of PFO-associated stroke over a five-year time horizon. Treatment options included GORE ® CARDIOFORM Septal Occluder (GSO Device), Amplatzer™ Talisman PFO Occluder (ATO Device), and Medical Therapy Alone. Effectiveness data were drawn from the REDUCE and RESPECT trials and prior cost-effectiveness analyses (CEAs). No head-to-head clinical trial comparing the ATO and GSO Device was identified; therefore, comparative clinical effectiveness estimates were derived from a matching-adjusted indirect comparison (MAIC). Costs were assessed from a UK payer perspective (2023 GBP). Outcomes included quality-adjusted life-years (QALYs), prevented strokes, incremental cost-effectiveness ratio (ICER), and budget impact. Results: GSO Device was estimated to be cost-saving and generate 24.66 additional QALYs versus ATO Device (dominant ICER) over five years and in a cohort of 1000 patients. Compared with Medical Therapy Alone, it provided 406.66 additional QALYs at an ICER of £ 14,343/QALY. It also prevented 27.86 and 67.05 strokes versus ATO Device and Medical Therapy Alone, respectively. Conclusion: The use of GSO Device is a cost-effective option for the prevention of secondary PFO-associated strokes, with favorable estimated clinical outcomes. Future studies providing direct comparative evidence between GSO and ATO could further inform the relative clinical and cost-effectiveness of available PFO closure devices.
No takes yet. Share an insight, caveat, or question.
Bentham et al. (2026) studied PFO-associated stroke (n=1,000). GORE CARDIOFORM Septal Occluder (GSO Device) vs. Amplatzer Talisman PFO Occluder (ATO Device) and Medical Therapy Alone was evaluated on Quality-adjusted life-years (QALYs) and Incremental cost-effectiveness ratio (ICER). The GSO Device was cost-saving and generated 24.66 additional QALYs versus the ATO Device, and provided 406.66 additional QALYs at an ICER of £14,343/QALY compared to medical therapy alone over 5 years.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: