Key result
Low left atrial compliance is linked to ~120% higher AF recurrence risk after catheter ablation.
Why the study?
The physiological and clinical implications of left atrial compliance in atrial fibrillation patients with structurally and functionally normal heart were not well understood.
Does low left atrial compliance increase the risk of clinical recurrence of atrial fibrillation after catheter ablation in patients with structurally and functionally normal hearts?
Cohort (n=334)
Does low left atrial compliance increase the risk of clinical recurrence of atrial fibrillation after catheter ablation in patients with structurally and functionally normal hearts?
Low left atrial compliance, indicated by elevated LA pulse pressure, is an independent predictor of AF recurrence after catheter ablation in patients with structurally normal hearts.
Answers are grounded in this paper and cite their sources.
Elevated LApp signals higher AF recurrence risk after ablation in normal hearts; leaves open whether LA compliance assessment refines selection or adjunctive strategies.
Stiff left atrial (LA) syndrome was initially reported in post-cardiac surgery patients and known to be associated with low LA compliance. We investigated the physiological and clinical implications of LA compliance by estimating LA pulse pressure (LApp) among patients with atrial fibrillation (AF) and structurally and functionally normal heart. Among 1038 consecutive patients with LA pressure measurements before AF ablation, we included 334 patients with structurally and functionally normal heart (81.7% male, 54.1±10.6 years, 77.0% paroxysmal AF) after excluding those with hypertension, diabetes, and previous ablation or cardiac surgery. We measured LApp (peak-nadir LA pressure) at the beginning of the ablation procedure and compared the values with clinical parameters and the AF recurrence rate. AF patients with normal heart were younger and more frequently male and had paroxysmal AF, a lower body mass index, and a lower LApp compared to others (all p<0.05). Based on the median value, the low LA compliance group (LApp≥13 mmHg) had a smaller LA volume index and lower LA voltage (all p<0.05) compared to the high LA compliance group. During a mean follow-up of 16.7±11.8 months, low LA compliance was independently associated with two fold-higher risk of clinical AF recurrence (HR:2.202; 95%CI:1.077-4.503; p = 0.031). Low LA compliance, as determined by an elevated LApp, was associated with a smaller LA volume index and lower LA voltage and independently associated with higher clinical recurrence after catheter ablation in AF patients with structurally and functionally normal heart.
No takes yet. Share an insight, caveat, or question.
Park et al. (2015) conducted a cohort in Atrial fibrillation with structurally and functionally normal heart (n=334). Low left atrial compliance (LApp ≥13 mmHg) vs. High left atrial compliance (LApp <13 mmHg) was evaluated on Clinical AF recurrence (HR 2.202, 95% CI 1.077-4.503, p=0.031). Low left atrial compliance was independently associated with a higher risk of clinical AF recurrence after catheter ablation.
Synapse has enriched 10 related papers. Consider them for comparative context: