A circuit capable of dividing 250 kV pulses by a ratio of 100,000 has been built and tested. It permits use of standard oscilloscopes to view high-speed transients that have components between 200 kHz and 200 MHz. The design is an adaptation of the guard ring principle, commonly used in electrostatic measurements.
No takes yet. Share an insight, caveat, or question.
Edson et al. (1981) studied this question.