Answers are grounded in this paper and cite their sources.
A high-temperature rheometer equipped with a graphite furnace, characterized by an air-bearing-supported synchronous motor, has been enhanced by a custom-made Pt-Au concentric cylinder assembly. With this adaptation, viscosity measurements of highly fluid melts can be achieved at high temperatures, up to 1273 K. Due to the air-bearing-supported motor, this apparatus can perform measurements of extremely low torque ranging between 0.01 μNm and 230 mNm (resolution of 0.1 nNm), extending the typical range of viscosity measurements accessible in the present configuration to 10- 3.5 -10 3.5 Pa.s and shear rates up to 10 2 of s -1 . We calibrated the system with distilled water, silicone oils, and the DGG-1 standard glass. We further present new data for the viscosity of Na 2 CO 3 , K 2 CO 3 , and Li 2 CO 3 liquids. Finally, a comparison between our results and literature data is provided, to illustrate the effect of chemical composition and oxygen fugacity on the viscosity of alkali carbonate melts, which serve as analogs for both carbonatitic melts and molten carbonates of industrial relevance. This study substantially improves the database of alkali carbonate melts and dramatically increases the accuracy with respect to previous measurement attempts. The very low viscosity range data and their temperature dependence also helps to constrain very well the activation energy of these highly fluid systems and confirms the estimate of a universal pre-exponential factor for non-Arrhenian visco sity-temperature relationships.
No takes yet. Share an insight, caveat, or question.
Genova et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: