One of the ongoing development challenges with ReBCO high-temperature superconducting (HTS) cables is normal zone initiation and local heating, which is associated with over-critical current flowing through and around local performance reductions in individual tapes. Although inter-tape contact resistances are well-reported for individual tapes and HTS cables, these measurements are a challenge in CORC® cables as current percolates through much of the cable. In this work, developments in tape-in-tape-out (TITO) automated individual tape powering experiments are presented, and a simplified modeling approach for current percolation in CORC® cables is developed. An optimization is formulated to fit the model parameters to a large set of TITO experiments on a single cable, allowing the layer-dependent inter-tape contact resistance to be extracted. Measurements are presented and discussed for a straight CORC® cable and a cable bent to a 152 mm and 76 mm radius. The approach provides both quantitative insight and facilitates better understanding of current sharing phenomena in HTS cables.
No takes yet. Share an insight, caveat, or question.
Teyber et al. (2025) studied this question.