The initial experience in 25 patients of using the Koh Colpotomiser System in conjunction with the RUMI Manipulator, a new modified technique for performing total laparoscopic hysterectomy, is presented. Of 25 operations, 23 (92%) were completed successfully. Complications were limited to minor pre-operative haemorrhage in two patients and post-operative bleeding in another. The Koh Colpotomiser System successfully maintained a pneumoperitoneum following colpotomy, giving the operator improved visibility and access to the pelvic organs. This resulted in greater efficiency, while eliminating the difficulties of vaginal access.
No takes yet. Share an insight, caveat, or question.
Keriakos et al. (2000) studied this question.