Steady state constant pressure diffusion measurements were made on a series of alumina pellets using the nitrogen‐helium system at 1 atm. and 80°F. The pellets were prepared from the same alumina powder but compressed to different densities. Pore size distribution data indicate that all the pellets had approximately the same micropore sizes and volume, but different macropore volumes. Flow measurements with nitrogen were also carried out for the same pellets over a pressure range, up to 1 atm. The data show that the pellet density, or macropore volume, has a pronounced effect On the basis of a simplified model of the pellet, path lengths were evaluated from the flow data. On the assumption that the diffusion path length is the same, a method is presented for predicting diffusion rates. The results so computed are independent of the path tortuosity. The method correctly evaluates the effect of pellet density on diffusion, but measured rates are 40 to 80% of the calculated values.
No takes yet. Share an insight, caveat, or question.
Robertson et al. (1963) studied this question.