Answers are grounded in this paper and cite their sources.
Current developments in structural biology and adjacent disciplines involve a complex integrative approach [1]. Resolving the details of biological structures with (sub-)nanometer resolution has become a necessary requirement, along with the need to visualize and understand the dynamics of the (bio)reactions governing different processes [2]. CryoEM and X-ray crystallography have emerged as the “gold standard” techniques in both academic research and in the pharmaceutical industry. These techniques provide structural information with extremely high resolution, however, capturing the process of the reaction in a native environment remains a challenge. Liquid-phase transmission electron microscopy (LPTEM) has emerged as a powerful tool capable of providing unprecedented insights into the dynamics of various processes [3]. However, technical challenges such as liquid thickness and radiational damage make LPTEM experiments complicated, especially for biological objects. To address the challenges posed by the aforementioned technical obstacles in LPTEM, we have developed the STREAM system for biological sample studies. STREAM is a plug-and-play system that relies on a microfluidic Lab-on-a-Chip device as a smart sample carrier. The latter allows to maintain a sample in its native liquid environment inside the TEM. STREAM comprises two main components: the liquid supply system (LSS) and a holder with microfluidic Lab-on-a-Chip device, referred to as the “Nano-Cell” (Fig. 1). The LSS allows for the flow of liquid or gas through the holder and Nano-Cell, and enables control over the pressure inside the Nano-Cell during the experiment by applying positive or negative pressure at the inlet or outlet of the holder. This capability of applying controlled pressure inside the Nano-Cell was utilized to reduce the liquid thickness for the magnetotactic bacteria (MTB) as a test specimen. The suspension of MTBs was drop-casted onto the bottom chip before the Nano-Cell was assembled. In such a liquid cell, the liquid remains very thick inside the microscope, making the bacteria invisible (Fig. 2a). However, after applying positive pressure at the inlet to create a stream of gas (air or any other inert gases) directed inside the Nano-Cell, the gas stream “purges” the excess liquid [4]. After the “purging”, the liquid thickness reduces, and the bacteria become visible (Fig. 2b). To mitigate radiation damage under the beam, the top chip of the Nano-Cell can be covered with monolayer graphene, which has been proven to reduce beam damage for biological samples during TEM imaging [5]. In this way, the combination of the “purging” capabilities of the SREAM system with graphene-covered Nano-Cells makes it possible to reduce the effects of high liquid thickness and radiation damage. This opens the way for LPTEM to become a more popular tool for studying biological objects, understanding reaction mechanisms, and visualizing the real-time dynamics with high resolution. LPTEM can become the perfect complementary technique to widely accepted structural biology tools like cryoEM and X-ray crystallography. Stream System. The plug-and-play solution relies on a Liquid Supply System (LSS) to flow the liquid into the holder, where the Nano-Cell is. The latter is a dual-cell chip device, with integrated microheater and/or biasing electrodes, where the top chip is coated with a monolayer graphene as a chemical scavenger to fight radiation damage. Part of viewing window in liquid cell. a) Before purging, W- edge of viewing window. b) After purging, magnetotactic bacteria (MTB) became visible.
No takes yet. Share an insight, caveat, or question.
Pechnikova et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: