Tailored mechanical properties of bone have been reported, whereas the interplay between healthy and osteoporotic bones has not yet been addressed. It is then important to understand the impact of osteoporosis on bone mechanical properties to design biomimetic materials suitable for orthopaedic implants. In this study, we have designed and compared two different unit cell structures: a single TPMS (Single TPMS and two interpenetrated variants, tailored to mimic and simulate different osteoporosis stages through relative density variations, considering biomechanical responses under compression strain load. The results demonstrated a correlation between the isovalue (C) and strain stiffness, where lower C values corresponded to higher relative density. Interestingly, the adopted specific energy absorption to maximum transmitted strength (SEA/MTS) capabilities achieved with a maximum of 3.9 J/g*MPa were achieved under quasi-static compression. Furthermore, the optimal stiffness obtained ranged from 0.74 MPa to 4.73 MPa, depending on the TPMS design (single or double). Thus, it is found that osteoporotic bone at a stage below 50% but not less than 20% of relative density loss could bear the strain based on the load applied. The results clearly show the development of novel orthopaedic lightweight implants with tailored properties for various biomedical applications.