The standard test method used to determine the hydraulic conductivity of a clean granular soil (rigid-wall permeameter –constant head difference) requires that the specimen be saturated with an air-vacuum pump. However, no method is provided to verify whether the sample is fully (100%) saturated. This paper proposes such a method and establishes its accuracy. The method allows for quality control of the rigid-wall permeameter itself: it can detect if it is watertight but not airtight, according to the achieved degree of saturation. A detailed example is given on a proposed data sheet. The reasons for partial saturation and the problems related to air bubbles are examined. The result of this examination is a simplified test to check a permeameter, based on the fact that for unsaturated conditions the hydraulic conductivity depends on which of two ways the water seeps in a given direction. A few modifications in the preparation of the specimen and the test procedure are suggested so as to improve the quality of test results.
No takes yet. Share an insight, caveat, or question.
Chapuis et al. (1989) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: