We demonstrate a 3× thermal phase sensitivity reduction for a hollow-core fiber (HCF) Fabry-Perot interferometer by winding the already low temperature sensitivity HCF on to a spool made from an ultralow thermal expansion material. A record low room temperature fiber coil phase thermal sensitivity of 0.13 ppm/K is demonstrated. The result is of particular interest in reducing the thermal sensitivity of HCF-based Fabry-Perot interferometers (for which existing thermal sensitivity reduction methods are not applicable). Our theoretical analysis predicts that significantly lower (or even zero) thermal sensitivity should be achievable when a spool with a slightly negative coefficient of thermal expansion is used. We also suggest a method to fine-tune the thermal sensitivity and analyze it with simulations.