Answers are grounded in this paper and cite their sources.
We propose a low-cost passive method for monitoring long-term average levels of light-absorbing carbon air pollution in polluted indoor environments. Building on prior work, the method here estimates the change in reflectance of a passively exposed surface through analysis of digital images. To determine reproducibility and limits of detection, we tested low-cost passive samplers with exposure to kerosene smoke in the laboratory and to environmental pollution in 20 indoor locations. Preliminary results suggest robust reproducibility (r = 0.99) and limits of detection appropriate for longer-term (~1–3 months) monitoring in households that use solid fuels. The results here suggest high precision; further testing involving “gold standard” measurements is needed to investigate accuracy.
No takes yet. Share an insight, caveat, or question.
Clark et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: