Key result
Higher CPB microemboli linked to elevated postoperative neurologic injury biomarker S100beta.
Why the study?
Previous research has associated cerebral microemboli from cardiopulmonary bypass circuits with neurologic injury biomarkers, but the relationship remains to be clarified.
Is exposure to microemboli from the cardiopulmonary bypass circuit associated with increased serum S100beta levels in patients undergoing coronary artery bypass grafting?
Observational (n=71)
No
Is exposure to microemboli from the cardiopulmonary bypass circuit associated with increased serum S100beta levels in patients undergoing coronary artery bypass grafting?
p-value: p=.03
Higher microembolic load from the cardiopulmonary bypass circuit during CABG is associated with increased postoperative serum S100beta, a biomarker of neurologic injury.
Neurologic biomarkers post-CPB lack validation for clinical use; Level 4 data leaves open any microemboli link.
An increasing number of reports surrounding neurologic injury in the setting of cardiac surgery has focused on utilizing biomarkers as intermediate outcomes. Previous research has associated cerebral microemboli and neurobehavioral deficits with biomarkers. A leading source of cerebral microemboli is the cardiopulmonary bypass (CPB) circuit. This present study seeks to identify a relationship between microemboli leaving the CPB circuit and a biomarker of neurologic injury. We enrolled 71 patients undergoing coronary artery bypass grafting at a single institution from October 14, 2004 through December 5, 2007. Microemboli were monitored using Power-M-Mode Doppler in the inflow and outflow of the CPB circuit. Blood was sampled before and within 48 hours after surgery. Neurologic injury was measured using S100beta (microg/L). Significant differences in post-operative S100beta relative to microemboli leaving the circuit were tested with analysis of variance and Kruskal-Wallis. Most patients had increased serum levels of S100beta (mean .25 microg/L, median .15 microg/L) following surgery. Terciles of microemboli measured in the outflow (indexed to the duration of time spent on CPB) were associated with elevated levels of S100beta (p = .03). Microemboli leaving the CPB circuit were associated with increases in postoperative S100beta levels. Efforts aimed at reducing microembolic load leaving the CPB circuit should be adopted to reduce brain injury.
No takes yet. Share an insight, caveat, or question.
Groom et al. (2010) conducted an observational in Coronary artery bypass grafting (n=71). Microemboli leaving the cardiopulmonary bypass (CPB) circuit vs. Lower terciles of microemboli was evaluated on Post-operative S100beta levels (p=.03). Higher terciles of microemboli leaving the cardiopulmonary bypass circuit were significantly associated with elevated postoperative levels of the neurologic injury biomarker S100beta (p = .03).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: