Key result
Transapical Melody valve-in-ring implantation successfully seals a partially detached annuloplasty ring, eliminating MR.
Why the study?
Partial dehiscence of prosthetic mitral rings is a major contraindication for valve-in-ring procedures due to ineffective sealing.
Does a customised Melody valve implant achieve proper sealing in a patient with a dehisced mitral annuloplasty ring?
Case Report (n=1)
Does a customised Melody valve implant achieve proper sealing in a patient with a dehisced mitral annuloplasty ring?
This first-in-man case demonstrates that a customised Melody valve can achieve successful sealing in a valve-in-ring procedure despite partial annuloplasty ring dehiscence.
Supports feasibility of customised Melody valve-in-ring for partial ring dehiscence; leaves open durability and generalizability.
AIMS: A "valve-in-ring" (ViR) procedure involves the transcatheter implant of a valved stent in a prosthetic mitral ring. The presence of a partial dehiscence of the prosthetic ring is a major contraindication for a ViR due to inefficacious sealing. We describe an alternative method of ViR implant to achieve proper valve sealing in the case of ring dehiscence. METHODS AND RESULTS: A 76-year-old male patient suffered from severe central mitral regurgitation due to annuloplasty ring dehiscence and leaflet tethering. ECG-gated multidetector computed tomography was used for preoperative planning. Standard transapical access was gained through a minimally invasive left thoracotomy in the 5th intercostal space. A customised Melody valve with two PTFE sutures fixed to the apex was used. The intervention was performed without complications, the patient recovered well, and transthoracic echo revealed no mitral regurgitation through the implanted valve with a transvalvular gradient of 4 mmHg. CONCLUSIONS: The implantation of a long covered stent such as the Melody valve allows successful sealing following a ViR even in case of partially detached annuloplasty rings. This procedure is a proof of concept that proper sealing can be achieved at the leaflet level without the use of radial force at the annular level.
No takes yet. Share an insight, caveat, or question.
Maisano et al. (2014) conducted a case report in Severe central mitral regurgitation due to annuloplasty ring dehiscence and leaflet tethering (n=1). Transapical valve-in-ring implant using a customised Melody valve was evaluated on Procedural success and valve sealing. Transapical valve-in-ring implantation using a customised Melody valve successfully sealed a partially detached annuloplasty ring, resulting in no mitral regurgitation and a 4 mmHg gradient.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: