Answers are grounded in this paper and cite their sources.
Reviewers; Primary Reviewer David Arbon RN BNsg. ([email protected]) Master of Clinical Science candidate. The Joanna Briggs Institute, The University of Adelaide, S A 5005. Secondary reviewer Dora Lang Siew Ping RN, BSN, Advanced Diploma Nursing (Oncology) Master of Clinical Science candidate. The Joanna Briggs Institute. The University of Adelaide. Principal Supervisor; Prof. Judy Lumby AM, RN, PhD, MHPEd. BA, FCN (NSW), FRCNA. Secondary Supervisor; Dr. Catalin Tufanaru MD, MPH. Review Objective The principle objective of this review will be to critically appraise and present the best available evidence for setting different levels of vacuum / suction pressures when patients are receiving endotracheal suctioning. Specifically the review will seek to answer the following questions. What is the best evidence for regulating vacuum pressure in the performance of endotracheal suctioning? What is the best evidence for regulating vacuum pressure for endotracheal suction as opposed to setting no regulated pressure in the performance of endotracheal suctioning? What is the best evidence for a limit to which vacuum should be regulated for endotracheal suction? To what extent does the developed airflow impact on the safety and effectiveness of the suction apparatus? Background Endo-tracheal suctioning, an essential component in the management of airway patency and secretion removal in the critically ill, has become a routine part of care for mechanically ventilated patients in the Intensive Care Unit. 1,2 The artificial airway mechanically disrupts the muco-cilliary escalator resulting in a pooling of secretions below the endotracheal tube that will need to be removed by the suction catheter1,2. Furthermore the Endotracheal (ET) tube itself is inclined to become occluded with bio-films after a short period insitu2, making it necessary to perform this suctioning of the airway to keep the airway patent and remove respiratory secretions as part of the care of the intubated patient. Various risks are involved in the procedure and have been reported since the earliest days of invasive respiratory support including “death by suctioning”.3,4 these risks include; Atelectasis; Reported and shown by radiological exam as early as the 1940's 3,5,6 Pulmonary haemorrhage has been seen with rapid decompression of segmental lung, with mechanical trauma from catheter impaction or sudden explosive decompression.7-9 Tissue trauma has been reported from the vigorous insertion of the suction catheter or impaction as the tissue lining the airway is suctioned into the side ports of the catheter.7,10,11 Negative pressure pulmonary oedema may be a result of the negative intrapulmonary pressure across the alveolar capillary bed. Negative pressure pulmonary oedema is sequel to sudden reduction suction in air pressure at the alveolar level. This is more often seen in cases of laryngeal-spasm after surgery.12-15 In Australia medical suction from a piped source should comply with Australian Standard AS 2120.3 1992.16 The United States Standard is similar, NFPA 99 5.1.12.3.10.4. The unguarded outlet in a modern hospital piped vacuum system may have an occlusion pressure of around 80kPa below atmospheric pressure and develop a flow though the outlet of over 80 Litres a minute17. This vacuum may then be used directly to clear a large amount of blood or vomitus from an operation site or oropharynx or regulated to an appropriate level for thoracic suction or removal of exudates from a healing wound. An examination of current evidence based research reveals a recommendation that a regulated suction pressure of 80mm Hg to 150mm Hg be set prior to performing endotracheal suctioning in the Adult patient suggesting this may be increased to 200mm Hg if secretions prove difficult to clear.1,2,18 Even so, in many intensive care units this suction is taken directly from the wall mounted high pressure suction outlet and the hospital piped vacuum system, a simple on / off tap being fitted which may deliver a vacuum level which has been described as being between effective and unsafe.19-21 From this we see a very large difference between theory and practice in some institutions and an invitation for further investigation. A search of the references quoted in these systematic reviews and meta analysis of the endotracheal suctioning proceedure1,2,18, leads back to the work of Rosen and Hillard in the 1960s and their investigation into the physical properties of hospital suction systems and their application to patient care.3,22 This research was among the first to recommend using a suction catheter that occluded less than half the internal diameter of the endotracheal tube in order to prevent the build up of large negative intra-pulmonary pressures during the suctioning procedure as there would be sufficient return airflow down the endotracheal tube to compensate for that removed by the suction catheter within the lung. Choosing a size of suction catheter is complicated by the common misunderstanding of Charriere's French scale commonly used for labelling suction catheters. While converting the French scale to mm merely involves dividing the number by 3, many persist in complicating the issue by using inaccurate mnemonics and calculations such as times the ET size by two and minus two which of course gives 14fr. for a size 8 ID (internal diameter) tube. This issue is further complicated by considering that it may be better to think about the area of the lumen taken up by the area of the circle created by the suction catheter2. Another aspect of this issue to come out of the seminal work of Drs. Hillard and Rosen is the fact that it is the air flow generated by a vacuum through a tube that actually is responsible for pushing the secretions into the suction catheter and creating the negative pressure in the pulmonary space.3,23 A cubic metre of air may weigh 1.2 kilograms at sea level and every litre 1.2grams. The weight of air moved by the more powerful vacuum will produce more work energy and a stronger suction force. As shown more recently in the work of Vanner, little intra pulmonary pressure drop with is seen with air flow rates up to 25 Litres / min., when the suction catheter occludes less than half the internal diameter of the endotracheal tube23. However in unpublished research, with assistance of the Biomechanical Engineering section of Flinders Medical Centre, in South Australia we have been able to measure some negative pressures developed in vitro using suction taken directly from the piped suction outlet. The research discovered that using the normal suction arrangement and a model similar to that used by Vanner, though minus the Anaesthetic machine, significant flows and subsequent negative pressures developed. A flow rate of some 56 litres / min was achieved through a size 14Fr catheter and 40 Litres / min through the size 12Fr catheter toward the occlusion pressure of 550mm Hg. These large flow rates may impose significant forces upon the small airways the results of which should be clarified by this review. When inserted through a size 8 Internal Diameter endotracheal tubes a negative pressure of over 8mm Hg is created using a size 14 (4.7mm) catheter and negative 4mm Hg when a size 12(4mm) suction catheter is used. Similar results were documented by Dr. Rosen in 1960 3. This increase is negative pressure as the ET tube narrows in relation to the suction catheter is an expression of the Bernoulli principle as the catheter within the endotracheal tube forms an annulus and resultant negative pressures may be calculated in compliance with the Hagen-Poiseuille Law 24,25. As the suction catheter is advanced further into the bronchi, current practice being to advance the catheter until resistance is felt and withdraw 2 cm before commencing to suction, the 50cm suction catheter tip may be found within a narrow branch of the bronchial tree some 18 cm beyond the end of the ET tube25. Advances in medical imaging make visible the rate at which the airways of the bronchial tree narrow so that an examination of these studies may help to clarify the issue of intrapulmonary vacuum pressure.26-28 it is a physical certainty that subsequent negative pressure within that area of lung will increase since as the further the catheter is inserted into a narrowing tube the higher resistance will create a higher level of negative pressure distally. A review of radiological findings in children before and after the implementation of regulated suction in a paediatric intensive care unit shows a significant statistical reduction in the incidence of right upper lobe collapse.6 Further studies have shown a reduction in adverse events when the catheter was advanced no more than 2 cm beyond the endotracheal tube29. Recent studies concerning the effects of endotracheal suction have been conducted in animal subjects. Research conducted by Hogmann in Sweden has noted the risks of lung injury at suction pressures of 14 kPa (120mm Hg),30. These findings appear in the published work of Almgren and colleagues10,20. Further animal and human studies have demonstrated airway collapse during suctioning using computed tomographic scans 31,32. It has been postulated that any loss of alveoli from sub-atmospheric pressure developing during suctioning may be detrimental and closed suction systems, whereby the patient may be suctioned without disconnection from the ventilator, has been promoted as a means of maintaining Positive End Expiration Pressure (PEEP) and hence lung volume during this procedure. The modern microprocessor controlled ventilator can deliver airflow to compensate for the flow being extracted by the suction catheter, maintaining lung volume. While traditionally a manual hyper-inflating series of breaths delivered by hand ventilator has been the method of choice for recruiting lung segments lost to atelectasis during suctioning, in recent times the concept of the ‘open lung’ has been developed discouraging disconnection from the ventilator and suggesting that even the loss of PEEP as the pressure within the lung returns to atmospheric on disconnection is to be avoided.33 The question then is how to perform this essential procedure without creating unwanted negative intrapulmonary pressure? In this review an examination research studies will be combined with a search for literature examining the effects of suctioning on airway compliance and lung function as well as the findings and reports of expert clinicians working in the field to synthesize a recommendation with regard to setting of a safe vacuum level for performing endotracheal suctioning. Prior to the commencement of this systematic review, the Cochrane Library, CINAHL and Joanna Briggs Institute (JBI) Library of systematic reviews were searched to ensure that no previous systematic reviews on this specific subject were identified or in progress. Inclusion Criteria Types of Participants Patients receiving mechanical ventilator support through endotracheal tube or tracheostomy in the acute care setting. Participants may present with a variety of pathologies but studies will not be excluded on the bases of diagnosis. Patients may require intubation and endotracheal suctioning at any age; vacuum applied in the performance of suction may have health implications and be of interest to the clinician. Papers regarding either spontaneously breathing and/or machine ventilated subjects will be also included so long as the participants require endotracheal suctioning in the acute stage of their hospitalisation. Types of intervention / Phenomena of interest The setting of a level of vacuum / suction pressure, taking into account the developed flow, to facilitate safe endotracheal suctioning in the acute care setting of the Intensive Care unit, High Dependency or Emergency Area will be examined. Types of outcomes Outcomes related to mortality, morbidity, and health benefits of regulating suction / vacuum pressure as opposed to having no regulation, i.e. Using the unguarded wall outlet, will be sought. The effects of negative pressure within the tracheo-bronchial tree including Atelectasis; Reported and shown by radiological exam as early as the 1940's 3,5,6 Pulmonary haemorrhage has been seen with rapid decompression of segmental lung, with mechanical trauma from catheter impaction or sudden explosive decompression.7-9 Tissue trauma has been reported from the vigorous insertion of the suction catheter or impaction as the tissue lining the airway is suctioned into the side ports of the catheter.7,10,11 Negative pressure pulmonary oedema may be a result of the negative intrapulmonary pressure across the alveolar capillary bed. Negative pressure pulmonary oedema is sequel to sudden reduction in air pressure at the alveolar level. This is more often seen in cases of laryngeal-spasm after surgery.12-15 Types of studies In keeping with the demands of a Systematic Review all quantitative studies that related to the objectives of the review will considered for inclusion. This review will consider any randomised-controlled trials that address the issue of suctioning artificial airways, specifically with regard to the effects of setting a suction or vacuum level. In the absence of randomised controlled trials specific to our question, other research designs will be assessed for inclusion using the following hierarchy as is applied for systematic review. Randomised Controlled Trials examining other aspects of this procedure will be considered for data extraction. Quasi-randomised control trials Quasi - experimental studies Cohort studies Cases controlled studies Case series Case reports Expert opinion. Search Strategy The search strategy aims to find both published and unpublished studies. An initial search using SUMMON at Adelaide university library will be undertaken in an attempt to cast as wide a net as possible using the terms found in the title of the review. Endotracheal / tracheal suctioning, looking at uncovering randomised control trials meta-analysis or expert guides to the procedure in general. This will be followed by analysis of the text words contained in the title and abstract, and of the index terms. A search will then be undertaken across a number of databases including but not limited to CINAHL, PUBMED and SCOPUS including those with a focus of medicine, nursing, biomedical engineering and imaging. Thirdly with a view to exposing all possible studies that relate or inform our outcomes of interest, the reference list of all identified reports and articles will be searched for additional studies. The search will include if possible the earliest reports from 1960, as these appear to be informing practice today, until the present. Published and unpublished hospital guidelines / procedure manuals will be searched Grey literature including papers from professional organisations as well as advice from experts working in the area. A search of reference lists and bibliographies for original sources will be made. Initial key words forming this initial search strategy will include; Endotracheal / tracheal suction pressures Endotracheal / tracheal suction vacuum Suction / vacuum setting for endotracheal suctioning Negative intrapulmonary pressure Medical suction systems Data Bases to be initially searched include; Summon at Adelaide University Library Scopus PubMed CINAHL Cochrane Library Oxford Journals Assessment of methodological quality Papers selected will be assessed by two independent reviewers for assessment of methodological quality using standardised tools from Joanna Briggs Institute Meta Analysis of Statistics and Review Instrument. (Appendix I) Any disagreements that arise between the reviewers will be resolved through discussion with a third reviewer. Data extraction / extraction Quantitative data will be extracted from papers included in the review using the standardised data extraction tool from JBI-MASTARI. The data extracted will include specific details about the interventions, population, study methods and outcomes of significance to the review question and specific objectives using a data extraction tool. (Appendix II) Data Synthesis Where possible, quantitative research study results will be pooled in a statistical meta-analysis using the Joanna Briggs Institute Meta Analysis of Statistics Assessment and Review instrument (JBI-MAStARI). All results will be subjected to double data entry. Odds ratio (for categorical data) and weighted mean differences (for continuous data) and their 95% confidence intervals will be calculated for analysis. Heterogeneity will be assessed using the standard chi-square. Where statistical pooling is not possible the findings will be presented in narrative form. Conflicts of Interest None known. Acknowledgement As this systematic review will contribute to the award of a MSc Clinical Science, a secondary reviewer will only be used for the processes of critical appraisal and data extraction.
No takes yet. Share an insight, caveat, or question.
David Arbon (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: