Recoil protons from the β-decay of unpolarized neutrons are stored in a cryogenic ion trap formed by the superposition of an axisymmetric electrostatic field on a coaxial magnetic field, which varies uniformly in space between regions of high (∼4.30 T) and low (∼0.61 T) homogeneous field. Protons generated in the high field region are adiabatically focused onto a 'mirror' electrode in the low field region. The integrated energy spectrum is determined by counting the number of stored protons as a function of mirror potential. Violation of the exact adiabatic conditions is corrected for by carrying out alternate measurements at trapping times which differ by a factor of 2. The results: a 0 = −0.1054 ± 0.0055, |λ| = 1.271 ± 0.018 are in agreement with previous measurements of these quantities.