Direct ionization from low energy protons is shown to cause upsets in a 65-nm bulk CMOS SRAM, consistent with results reported for other deep submicron technologies. The experimental data are used to calibrate a Monte Carlo rate prediction model, which is used to evaluate the importance of this upset mechanism in typical space environments. For the ISS orbit and a geosynchronous (worst day) orbit, direct ionization from protons is a major contributor to the total error rate, but for a geosynchronous (solar min) orbit, the proton flux is too low to cause a significant number of events. The implications of these results for hardness assurance are discussed.
No takes yet. Share an insight, caveat, or question.
Sierawski et al. (2009) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: