Key result
BeBack catheter for in situ fenestration during TEVAR achieves target vessel patency and false lumen exclusion.
Why the study?
The use of the BeBack re-entry catheter as an alternative tool for in situ fenestration during TEVAR to preserve the left subclavian artery in subacute type B aortic dissection was described.
Does the BeBack re-entry catheter allow successful in situ fenestration to preserve the left subclavian artery during TEVAR in a patient with subacute type B aortic dissection?
Case Report (n=1)
Does the BeBack re-entry catheter allow successful in situ fenestration to preserve the left subclavian artery during TEVAR in a patient with subacute type B aortic dissection?
The BeBack re-entry catheter is a feasible alternative tool for in situ fenestration to preserve the left subclavian artery during TEVAR.
Answers are grounded in this paper and cite their sources.
Single-case success with BeBack for in situ fenestration in TEVAR; hypothesis-generating and requires prospective validation before wider adoption.
We describe the use of the BeBack re-entry catheter as an alternative tool for in situ fenestration during thoracic endovascular aortic repair in a patient with subacute type B aortic dissection requiring zone 2 landing. A 69-year-old woman with high-risk imaging features underwent thoracic endovascular aortic repair with intentional coverage of the left subclavian artery. Via percutaneous left brachial access, a deflectable 7F introducer was positioned against the outer curvature of the thoracic endograft. Retrograde puncture was performed using a 4F × 120 cm BeBack re-entry catheter under angiographic guidance in orthogonal projections to ensure precise orientation and penetration. After successful crossing of the endograft fabric, an 0.018″ guidewire was advanced into the ascending aorta, followed by sequential dilation and deployment of a balloon-expandable stent. Final angiography confirmed patency of the target vessel and exclusion of the false lumen.
No takes yet. Share an insight, caveat, or question.
López et al. (2025) conducted a case report in Subacute type B aortic dissection (n=1). BeBack re-entry catheter-guided in situ fenestration was evaluated on Patency of the target vessel and exclusion of the false lumen. Use of the BeBack re-entry catheter for in situ fenestration during thoracic endovascular aortic repair successfully achieved target vessel patency and false lumen exclusion in a 69-year-old woman.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: