Key result
Epicardial colchicine-eluting mesh cuts POAF inducibility ~50% versus control in a swine pericarditis model.
Why the study?
Does biatrial epicardial colchicine-eluting bioresorbable polymer mesh reduce the inducibility of postoperative atrial fibrillation in a swine sterile pericarditis model?
Does biatrial epicardial colchicine-eluting bioresorbable polymer mesh reduce the inducibility of postoperative atrial fibrillation in a swine sterile pericarditis model?
A biatrial epicardial colchicine-eluting bioresorbable polymer mesh significantly reduced atrial inflammation and the inducibility of postoperative atrial fibrillation in a swine sterile pericarditis model.
Answers are grounded in this paper and cite their sources.
Local colchicine mesh attenuates POAF inducibility in swine pericarditis; hypothesis-generating for human postoperative AF trials.
Background Recent clinical trials have shown that colchicine, an anti‐inflammatory agent, is superior in preventing postoperative atrial fibrillation (POAF) in patients after open heart surgery. However, the systemic use of colchicine was associated with an increased incidence of gastrointestinal adverse effects, often leading patients to discontinue treatment. The objective of this study was to evaluate the effectiveness and safety of biatrial epicardial colchicine‐eluting bioresorbable polymer mesh for preventing POAF in a swine sterile pericarditis model. Methods Twelve domestic pigs underwent initial pericarditis surgery. During the creation of the swine sterile pericarditis model, either colchicine‐eluting bioresorbable mesh (0.5–1 mg/day, 6 pigs) or only bioresorbable mesh without the drug (6 pigs) was placed on both atria. On postoperative days 1 and 2, we measured the electrophysiological properties, including pacing threshold, atrial effective refractory period, and inducibility of POAF. Blood and tissue samples were obtained to assess systemic and local inflammation. Results The pacing threshold was significantly lower and the atrial effective refractory period was significantly longer in the colchicine‐treated pericarditis pigs compared with the pericarditis control pigs. The inducibility of POAF episodes was significantly lower in the colchicine‐treated pericarditis pigs (median of POAF episodes: 0, P <0.05; 3/6 pigs) compared with the pericarditis control pigs (median of POAF episodes: 1.5; 6/6 pigs). RNA sequencing analysis of local tissue revealed a decrease in differentially expressed genes associated with inflammation and cardiotoxicity in the colchicine‐treated group. Conclusions Biatrial epicardial colchicine‐eluting bioresorbable polymer mesh significantly diminished atrial inflammation, thereby reducing the inducibility of POAF in a swine sterile pericarditis model.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2026) studied Postoperative atrial fibrillation (n=12). Biatrial epicardial colchicine-eluting bioresorbable polymer mesh vs. Bioresorbable mesh without the drug was evaluated on Inducibility of POAF episodes (p=<0.05). Biatrial epicardial colchicine-eluting bioresorbable polymer mesh reduced the inducibility of POAF in a swine sterile pericarditis model compared to control mesh.
Synapse has enriched 10 related papers. Consider them for comparative context: