Key result
Digit serial Sign-Sign Least Mean Square filter increases processing speed ~55% vs bit serial filters.
Why the study?
Variants of Least Mean Square algorithms for ECG signal denoising have limitations in speed due to processing one bit per clock cycle in existing Sign-Sign adaptive filters.
The proposed digit serial architecture for the Sign-Sign Least Mean Square adaptive filter significantly increases processing speed and reduces area for ECG signal denoising compared to existing bit serial methods.
Answers are grounded in this paper and cite their sources.
Faster ECG denoising hardware may aid real-time monitoring; leaves open clinical validation and outcome impact.
Variants of Least Mean Square algorithm, namely the Sign Error, Sign Regressor and Sign-Sign Least Mean Square algorithms are meant for reducing computational complexity in digital adaptive filters in denoising electrocardiogram signals. In adaptive filtering using Sign-Sign algorithm, the adders and multipliers in the existing method take the coefficients in canonic signed power of two form which assures that between two non-zero there should be one zero in signed power of two digits and they can process only one bit per clock cycle and so is the filter resulting in low speed. In this paper, digit serial adder and digit serial multiplier are proposed to design the Sign-Sign Least Mean Square filter, which increases the speed by processing two bits per clock cycle. The digit serial adder and digit serial multiplier are used to design the Sign-Sign based adaptive filter in which unfolding technique is used for digit serial realisation. The unfolding factor of K = 2 is chosen to increase the speed of the design. The coefficients and its inputs are represented in Canonic Signed Digit form. Adder, multiplier, adaptive filter of both existing and proposed method are simulated using Mentor Graphics and synthesised using Synopsys Design Compiler Tool with 90 nm technology. From the results it is observed that the speed of the proposed digit serial Sign-Sign Least Mean Square filter is increased by 54.5% and the area of the filter is decreased by 4.21% compared to the bit serial Sign-Sign Least Mean Square filter.
No takes yet. Share an insight, caveat, or question.
Sasikala et al. (2017) studied ECG signal denoising. Digit serial architecture for Sign-Sign Least Mean Square adaptive filter vs. Bit serial Sign-Sign Least Mean Square filter was evaluated on Speed and area of the filter. The proposed digit serial Sign-Sign Least Mean Square filter increased processing speed by 54.5% and decreased area by 4.21% compared to the bit serial filter.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: