Key result
Hybrid endovascular and open repair successfully treats a thoracic aortic pseudoaneurysm from a dislodged spinal screw.
Why the study?
Anterior thoracic arthrodesis can cause thoracic aortic pseudoaneurysms due to late screw loosening, but management strategies and complications are not well described.
Case Report (n=1)
Anterior vertebral hardware removal complicated by an aortic pseudoaneurysm is highly demanding and should be performed in a setting equipped for both endovascular and open aortic repair due to the risk of unexpected life-threatening complications.
Aortic injury risk during screw removal warrants caution in hybrid repairs; case report leaves optimal management of late loosening unresolved.
A few descriptions about anterior thoracic arthrodesis causing thoracic aortic pseudoaneurysms due to late screw loosening are mentioned in the literature. We report a case that describes a hybrid approach complicated with an aortic injury when removing a screw from the aortic wall. A 57-year-old man was initially operated on for scoliosis due to poliomyelitis using dorsal thoracolumbar in situ fusion at an early age. At adulthood, the patient complained of spinal cord compression and severe myelopathy due to D9-D10 nonunion, and the patient required a double surgical approach. Almost a year later, he was diagnosed with a thoracic aneurysm caused by late screw loosening from the anterior plate. A hybrid approach was used to treat the aortic pseudoaneurysm (endograft stent) and for anterior vertebral hardware removal (rethoracotomy). Although an aortic stent was covering the aortic lumen, during the open part of the procedure, an aortic injury took place when removing the screw, requiring quick cross clamping and repair. Anterior vertebral hardware removal after a previous anterior spinal approach is a technically highly demanding procedure. As unexpected life-threatening complications can occur, this procedure should be performed in a setting with the capacity for both endovascular and open aortic repair.
No takes yet. Share an insight, caveat, or question.
Egea-Gámez et al. (2020) conducted a case report in Thoracic aortic pseudoaneurysm due to screw dislodgment (n=1). Hybrid approach (endovascular stent and open rethoracotomy for screw removal) was evaluated on Successful management of aortic pseudoaneurysm and screw removal. A hybrid approach involving an endovascular stent followed by open rethoracotomy with cross-clamping and direct end-to-end aortic repair successfully managed a life-threatening thoracic aortic pseudoaneurysm caused by a dislodged spinal screw.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: