Key result
Automated videofluoroscopy tracking enables high-resolution tricuspid valve analysis but requires substantial manual marker identification.
Why the study?
Existing algorithms for fully automated tracking of radiopaque cardiac markers did not allow exact anatomical location assignment for each marker.
Case Report (n=1)
No
Fully automated tracking of radiopaque markers using high-frequency videofluoroscopy is feasible for quantitative cardiac analysis in an ovine model, though anatomical identification remains manual.
Answers are grounded in this paper and cite their sources.
Enables anatomically assigned marker tracking in ovine models; leaves open validation and clinical translation.
PURPOSE: Recently, algorithms were developed to track radiopaque markers in the heart fully automated. However, the methodology did not allow to assign the exact anatomical location to each marker. In this case study we describe the steps from the generation of three-dimensional marker coordinates to quantitative data analyses in an in vivo ovine model. METHODS: In one adult sheep, twenty silver balls were sutured to the right side of the heart: 10 to the tricuspid annulus, one to the anterior tricuspid leaflet and nine to the epicardial surface of the right ventricle. In addition, 13 cylindrical tantalum markers were implanted into the left ventricle. Data were acquired with a biplanar X-ray acquisition system (Neurostar R, Siemens AG, 500 Hz). Radiopaque marker coordinates were determined fully automated using novel tracking algorithms. RESULTS: The anatomical marker locations were identified using a 3-dimensional model of a single frame containing all tracked markers. First, cylindrical markers were manually separated from spherical markers, thus allowing to distinguish right from left heart markers. The fast moving leaflet marker was identified by using video loops constructed of all recorded frames. Rotation of the 3-dimensional model allowed the identification of the precise anatomical position for each marker. Data sets were then analyzed quantitatively using customized software. CONCLUSIONS: The method presented in this case study allowed quantitative data analyses of radiopaque cardiac markers that were tracked fully automated with high temporal resolution. However, marker identification still requires substantial manual work. Future improvements including the implication of marker identification algorithms and data analysis software could allow almost real-time quantitative analyses of distinct cardiac structures with high temporal and spatial resolution.
No takes yet. Share an insight, caveat, or question.
Bothe et al. (2016) conducted a case report in Cardiac mechanics (ovine model) (n=1). Radiopaque marker tracking using high-frequency videofluoroscopy was evaluated on Generation of three-dimensional marker coordinates and quantitative data analyses. Fully automated tracking of radiopaque cardiac markers using high-frequency videofluoroscopy allowed quantitative data analyses of the tricuspid valve complex with high temporal resolution, though marker identification still required substantial manual work.
Synapse has enriched 10 related papers. Consider them for comparative context: