Answers are grounded in this paper and cite their sources.
Extended field-of-view ultrasound (US EFOV) imaging is a technique used extensively in the clinical field to attain interpretable panorama of anatomy; 2.5-D US EFOV has recently been proposed for spine imaging. In the original 2.5-D US EFOV, it makes use of a six degrees-of-freedom positional sensor attached to the US probe to record the corresponding position of each B-scan. By combining the positional information and the B-scan images, the 2.5-D EFOV can reconstruct a panorama on a curved image plane when the scanning trajectory of the US probe is curved. In this paper, an improved method based on the Bezier interpolation is proposed to better reconstruct 2.5-D US EFOV imaging, producing the panoramas with smoother texture and higher quality. To make it more applicable for scoliosis patients, we designed a novel method called double-sweep 2.5-D EFOV to better image the spinal tissues and easily compute the Cobb angle. In vitro and in vivo experiments demonstrated that the 2.5-D EFOV images obtained by the proposed method can present anatomical structures of the scanning region accurately.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: