A modified fluidized bed reactor is developed to homogenously coat micrometer‐sized particles with reactive polymer films using CVD. This technique is found to be rapid (∼30 min per batch) and scalable (up to 1 g particles), and can create homogenous coatings on microparticles down to 10 μm in diameter. By tuning critical variables, such as working pressure and the carrier gas flow rate, full coverage of a reactive polymer film can be realized. Janus particles are synthesized and can be visualized via fluorescence microscopy.
No takes yet. Share an insight, caveat, or question.
Liang et al. (2015) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: