Liquid chromatographic separation of zinc isotopes was attempted in the breakthrough manner using benzo-15-crown-5 resin as column packing material at 313 K, and a 20 m long development was successfully achieved. The value of the single-stage separation factor was 1.00035 for the 66Zn/64Zn isotopic pair, 1.00047 for 67Zn/64Zn pair, and 1.00060 for the 68Zn/64Zn pair, which were equivalent to those obtained by a 5 m long chromatographic experiment under the same conditions. Contrary to this, the HETP value was 0.19 cm at the 20m development while it had been 0.09 cm at the 5 m development. Connecting separation columns with polytetrafluoroethylene tubes not packed with the resin may be responsible for this migration distance dependence of the HETP.
No takes yet. Share an insight, caveat, or question.
Fukuda et al. (2006) studied this question.