Answers are grounded in this paper and cite their sources.
In this paper, we experimentally verified the length (LESC) and the concentration (cESC) of the extended space charge (ESC) layer in front of the electrical double layer (EDL) using the chronopotentiometric measurement and the equivalent circuit model analysis. From the experimentation, the coupled-response of the EDL and the ESC layer was discriminated from the contribution of electro-osmotic flow (EOF). In addition, we derived the potential differences across the ESC (VESC) layer using the circuit model of the ICP layer under rigorous consideration of ESC and EDL. As a result, we obtained that VESC was linearly proportional to the square of the applied current (iapplied). Hence, LESC and cESC were quantitatively provided, where LESC is linear to the iapplied and cESC is constant regardless of iapplied. Thus, this experimentation could not only clarify an essential ICP theory but also guide in ESC-based applications.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2020) studied this question.