In this paper, an extended version of the continuous class-F-1mode power amplifier (PA) design approach is presented. A new formulation describing the current waveform in terms of just two additional parameters, while maintaining a constant half-wave rectified sinusoidal voltage waveform, allows multiple solutions of fundamental and second-harmonic impedances that provide optimum performance to be computed. By varying only the imaginary parts of fundamental and second-harmonic impedances, it is shown that output performance in terms of power and efficiency is maintained constant and equal to that achievable from the standard class-F-1. Indeed, when presenting resistive second-harmonic impedances, it will be demonstrated that the fundamental load can be adjusted to maintain satisfactory output performances greater than a certain predetermined target value. The measurements, conducted on a GaAs pHEMT device at 1 GHz, show a good agreement with the theoretical analysis, revealing drain efficiencies greater than 70% for a very large range of load solutions, which can translate to an ability to accommodate reactive impedance variations with frequency when designing broadband PAs.
No takes yet. Share an insight, caveat, or question.
Carrubba et al. (2012) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: